Configure Remote SPBM Parameters on the Interface
About this task
Perform this procedure to configure the remote SPBM interface parameters.
Procedure
- In the navigation pane, expand the folders.
- Select SPBM Remote.
- Select the Interfaces SPBM tab.
- Select Insert to create a remote SPBM instance on the interface.
- Configure the remote SPBM interface parameters.
- Select Insert.
Interfaces SPBM Field Descriptions
Use the data in the following table to use the Interfaces SPBM tab.
Name |
Description |
---|---|
Index |
Specifies an Index value for the remote SPBM interface. |
SpbmId |
Specifies the remote SPBM ID. |
State |
Specifies whether the remote SPBM interface is enabled or disabled. |
Type |
Configures the remote SPBM instance interface-type on the IS-IS interface on the specific port or MLT, the values are point-to-point (ptpt) or broadcast (bcast). The system supports the ptpt interface type only. |
L1Metric |
Configures the remote SPBM instance l1-metric on the IS-IS interface on the specific port or MLT. The default value is 10. |
Origin |
Specifies the source of the remote SPBM instance configuration.
|