Configure Remote SPBM Parameters on the Interface

About this task

Perform this procedure to configure the remote SPBM interface parameters.

Procedure

  1. In the navigation pane, expand the Configuration > Fabric folders.
  2. Select SPBM Remote.
  3. Select the Interfaces SPBM tab.
  4. Select Insert to create a remote SPBM instance on the interface.
  5. Configure the remote SPBM interface parameters.
  6. Select Insert.

Interfaces SPBM Field Descriptions

Use the data in the following table to use the Interfaces SPBM tab.

Name

Description

Index

Specifies an Index value for the remote SPBM interface.

SpbmId

Specifies the remote SPBM ID.

State

Specifies whether the remote SPBM interface is enabled or disabled.

Type

Configures the remote SPBM instance interface-type on the IS-IS interface on the specific port or MLT, the values are point-to-point (ptpt) or broadcast (bcast). The system supports the ptpt interface type only.

L1Metric

Configures the remote SPBM instance l1-metric on the IS-IS interface on the specific port or MLT. The default value is 10.

Origin

Specifies the source of the remote SPBM instance configuration.

  • config - configure manually through CLI or EDM.
  • dynamic - configure dynamically through Auto-sense.