Configure EAP auto-isid-offset
Note
This procedure does not apply to VSP 4450 Series, VSP 8600 Series, or XA1400 Series.
Before you begin
- Enable EAP globally or on the port.
Procedure
Examples
Configure an I-SID offset value and enable I-SID offset globally on the switch:
Switch:1> enable Switch:1#config terminal Enter configuration commands, one per line. End with CNTL/Z. Switch:1(config)#eapol auto-isid-offset 1000 Switch:1(config)#eapol enable
View the current device configuration:
Switch:1>show eapol system ================================================================================ Eapol System ================================================================================ eap : disabled Eapol Version : 3 non-eap-pwd-fmt : mac-addr non-eap-pwd-fmt key : ****** non-eap-pwd-fmt padding : disabled auto-isid-offset status : disabled auto-isid-offset value : 1000
Variable Definitions
The following table defines parameters for the eapol auto-isid-offset command.
Variable |
Value |
---|---|
<0-15995903> |
Specifies the auto I-SID offset value. The default is 15995903. |
enable |
Enables auto I-SID offset. The default is disabled. |