Configure Autogenerated CFM on C-VLANs
Use this procedure to configure the autogenerated CFM MEP and MIP level for every C-VLAN on the chassis.
To configure autogenerated CFM on SPBM B-VLANs, see Configure Autogenerated CFM on SPBM B-VLANs.
Note
For C-VLANs, you can only use autogenerated CFM MEPs.
Important
CFM supports one MEP or MIP on each C-VLAN. Only autogenerated CFM provides support for configuring MEP and MIPs on C-VLANs. You cannot explicitly configure C-VLANs.
About this task
When you enable this feature, you create a global MD (named cmac) for all the customer MAC (C-MAC) MEPs. This MD has a default maintenance level of 4, which you can change with the level attribute. The autogenerated CFM commands also create an MA for each C-VLAN, a MEP for each C-VLAN, and associate the MEP with the corresponding C-VLAN and a MIP with the C-VLAN.
All the MEPs that the device creates use the MEP ID configured under the global context, which has a default value of 1. The device automatically associates the MEPs with the C-VLANs configured. The MIP level maps to the global level. The device automatically associates the MIP level with the C-VLANs configured when you enable the feature.
The feature is disabled by default.
Procedure
- In the navigation pane, expand .
- Select CFM.
- Select the Global tab.
- Select enable next to CmacAdminState.
- In the fields provided, specify a maintenance level and a MEP ID.
- Select Apply.
Global Field Descriptions
Use the data in the following table to configure the global MEP and MIP parameters.
Name |
Description |
---|---|
SpbmAdminState |
Enables or disables autogenerated CFM for B-VLANs. The default is disable. |
SpbmLevel |
Specifies the global SPBM CFM maintenance level for the chassis within the range of 0 to 7. The default is 4. Only configure global CFM at one MD level for each chassis for each VLAN type. |
SpbmMepId |
Specifies the global MEP ID within the range of 1 to 8191. Select a unique ID for each switch to ensure that the MEPs are unique across the network. The default is 1. |
CmacAdminState |
Enables or disables autogenerated CFM for C-VLANs. The default is disable. This field does not apply for all hardware platforms. |
CmacLevel |
Specifies the global C-MAC CFM maintenance level for the chassis within the range of 0 to 7. The default is 4. Only configure global CFM at one MD level for each chassis for each VLAN type. This field does not apply for all hardware platforms. |
CmacMepId |
Specifies the global MEP ID within the range of 1 to 8191. Select a unique ID for each switch to ensure that the MEPs are unique across the network. The default is 1. This field does not apply for all hardware platforms. |
Bmac |
Displays the B-MAC address of the node. This field does not apply for all hardware platforms. |
Cmac |
Displays the C-MAC address of the node. This field does not apply for all hardware platforms. |