BPDU Guard

Table 1. Bridge Protocol Data Unit (BPDU) Guard product support

Feature

Product

Release introduced

Bridge Protocol Data Unit (BPDU) Guard

5320 Series

Fabric Engine 8.6

5420 Series

VOSS 8.4

5520 Series

VOSS 8.2.5

5720 Series

Fabric Engine 8.7

7520 Series

Fabric Engine 8.10

7720 Series

Fabric Engine 8.10

VSP 4450 Series

VOSS 6.0

VSP 4900 Series

VOSS 8.1

VSP 7200 Series

VOSS 6.0

VSP 7400 Series

VOSS 8.0

VSP 8200 Series

VOSS 6.0

VSP 8400 Series

VOSS 6.0

VSP 8600 Series

VSP 8600 6.2

XA1400 Series

Not Supported

The switch supports Bridge Protocol Data Unit (BPDU) Guard for STGs, RSTP, and MSTP.

Overview

Spanning Tree eliminates loops in a network. A bridge that participates in spanning tree uses BPDUs to exchange information with other bridges. The bridges select a single bridge as the root bridge based on the BPDU information exchange. The bridge with the lowest priority becomes the root bridge. If all bridges share the same priority, the bridge with the lowest bridge ID becomes the root bridge. This process is the root selection process.

After you add a new bridge to the network, or remove an existing bridge, the bridges repeat the root selection process, and then select a new root bridge.

To ensure the correct operation of Spanning Tree in the network, BPDU Guard protects the stability of the Root Bridge by dropping stray, unexpected, or unwanted BPDU packets entering a port, and immediately shutting down those ports for a specified time period. BPDU Guard is normally enabled on access ports connecting to end user devices such as servers that are not expected to operate Spanning Tree.

Use BPDU Guard to achieve the following results:

Operation

You can enable or disable BPDU Guard on an individual port basis, regardless of the spanning tree state. Each port uses a timer to determine port-state recovery.

After you enable BPDU Guard on a port and the port receives a BPDU, the following actions occur:

  1. The guard disables the port.

  2. The switch generates an SNMP trap and alarm, and the following log message:

    BPDU Guard - Port <slot/port> is being shutdown by BPDU Guard, timeout <time_seconds>

  3. The port timer begins.

  4. The port remains in the disabled state until the timer expires.

If you disable BPDU Guard before the timer expires, the timer stops and the port remains in the disabled state. You must manually enable the port.

BPDU Guard is enabled at the interface level. You can configure the BPDU Guard timer for each port, for 10 to 65535 seconds. If you set the port timer to zero, it will not expire.