Configure the Guest I-SID

Note

Note

This procedure does not apply to VSP 8600 Series or XA1400 Series.

Before you begin

Configure a platform VLAN and associate the Guest I-SID. 0 indicates that Guest I-SID is not enabled for this port.

About this task

Use this procedure to configure the Guest I-SID.

Procedure

  1. Enter GigabitEthernet Interface Configuration mode:

    enable

    configure terminal

    interface GigabitEthernet {slot/port[/sub-port][-slot/port[/sub-port]][,...]}

    Note

    Note

    If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port.

  2. Configure the Guest I-SID:

    eapol guest-isid <1-16000000>

Example

Configure the Guest I-SID.

Switch:1>enable
Switch:1#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch:1(config)#interface gigabitEthernet 1/10
Switch:1(config-if)#eapol guest-isid 1000

Variable Definitions

The following table defines parameters for the eapol guest-isid command.

Variable

Value

<0-16000000>

Specifies the Guest I-SID value.

0 indicates that Guest I-SID is not enabled for this port.