Enable Channelization
Enable channelization on a port to configure it to operate as four channels, or ports.
Note
The switch automatically channelizes a port if the port operates in Auto-sense mode and you insert a QSFP+ to SFP+ or QSFP28 to SFP28 adapter, or a breakout cable.
About this task
Important
Enabling or disabling channelization resets the port QoS configuration to default values.
Procedure
Examples
Switch:1> enable Switch:1# configure terminal Switch:1(config)# interface gigabitethernet 2/1 Switch:1(config-if)# channelize enable Enabling channelization on port 2/1. Subport 2/1/1 will inherit port 2/1 configuration. Subports 2,3,4 will use default config. QSFP will be reset as removal and re-insert. NOTE: Modify QOS configurations on all subports as required. Do you wish to continue (y/n) ? y
Display the port status:
Switch:1(config)# show interfaces gigabitEthernet channelize 2/2-2/4 ================================================================================ Port Channelization ================================================================================ -------------------------------------------------------------------------------- PORT ADMIN MODE CHANNEL TYPE -------------------------------------------------------------------------------- 2/2 true 40G 2/3 false 40G 2/4 false 40G
The following is an example of how to disable channelization on a port:
Switch:1> enable Switch:1# configure terminal Switch:1(config)# interface gigabitethernet 2/2/1 Switch:1(config-if)# no channelize enable
The following example shows a device inserted into a port and auto channelized:
1 2022-10-14T12:30:44.365Z VSP-7432CQ CP1 - 0x000e0598 - 00000000 GlobalRouter HAL INFO GBIC inserted in slot 1 port 11 Type: 40GbCR4BoC Vender: <Vendor> 1 2022-10-14T12:30:46.368Z VSP-7432CQ CP1 - 0x00004749 - 00000000 GlobalRouter SNMP INFO Port 1/11 channelized state changed to true. 1 2022-10-14T12:30:48.483Z VSP-7432CQ CP1 - 0x000e0597 - 00000000 GlobalRouter HAL INFO GBIC removed from slot 1 port 11 Type: 40GbCR4BoC Vender: <Vendor> 1 2022-10-14T12:30:50.635Z VSP-7432CQ CP1 - 0x000e0598 - 00000000 GlobalRouter HAL INFO GBIC inserted in slot 1 port 11 Type: 40GbCR4BoC Vender: <Vendor> 1 2022-10-14T12:30:50.635Z VSP-7432CQ CP1 - 0x000e05fb - 00000000 GlobalRouter HAL INFO GBIC is active in channelized sub-port. Slot 1 port 11 Type: 40GbCR4BoC Vender: <Vendor> 1 2022-10-14T12:30:50.635Z VSP-7432CQ CP1 - 0x000e05fb - 00000000 GlobalRouter HAL INFO GBIC is active in channelized sub-port. Slot 1 port 11 Type: 40GbCR4BoC Vender: <Vendor> 1 2022-10-14T12:30:50.635Z VSP-7432CQ CP1 - 0x000e05fb - 00000000 GlobalRouter HAL INFO GBIC is active in channelized sub-port. Slot 1 port 11 Type: 40GbCR4BoC Vender: <Vendor> 1 2022-10-14T12:30:50.795Z VSP-7432CQ CP1 - 0x000e05fb - 00000000 GlobalRouter HAL INFO GBIC is active in channelized sub-port. Slot 1 port 11 Type: 40GbCR4BoC Vender: <Vendor>
Variable Definitions
The following table defines parameters for the channelization command.
Variable |
Value |
---|---|
{slot/port[/sub-port][-slot/port[/sub-port]][,...]} |
Identifies the slot and port in one of the following formats: a single slot and port (slot/port), a range of slots and ports (slot/port-slot/port), or a series of slots and ports (slot/port,slot/port,slot/port). If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port. |