Configure Ingress Policer and Port Rate Limiter

Note

Note

This procedure only applies to VSP 4900 Series and VSP 7400 Series switches.

Perform this procedure to limit the number of packets that can be attached to an ACL ACE. If you want to modify the ingress bandwidth rate limiter values, you must first disable the ACE.
Note

Note

You can attach one policer to ACL and ACE. Every policer is independent.

Before you begin

Ensure that both the ACL and the ACE exist.

Procedure

  1. In the navigation tree, expand Configuration > Security > Data Path.
  2. Select Advanced Filters (ACE/ACLs).
  3. Select the appropriate ACL.
  4. Select the appropriate ACE.
  5. Select Policer.
  6. Select Insert.
  7. For SvcRateValue, type the service rate value.
  8. For PeakRateValue, type the peak rate value.
  9. Select Insert.
  10. Select Apply.