Configuring an SPBM Layer 2 Transparent Port UNI
Use this procedure to configure a Transparent Port UNI or E-LAN Transparent service.

Note
If you are configuring a T-UNI to terminate on a port or MLT on a switch in a vIST switch cluster, you must also configure the T-UNI I-SID on the other switch of the vIST switch cluster. You must configure the T-UNI I-SID on both switches of a vIST pair. It is not necessary to assign an actual port or MLT to the T-UNI on the second switch.
Before you begin
- You must configure the required SPBM and IS-IS infrastructure, which includes creating the SPBM BVLANs. 
- You must associate a T-UNI LACP MLT with a VLAN before mapping the LACP MLT to a T-UNI I-SID.  - Caution - In the case of T-UNI LACP SMLT, before you configure SMLT on switch peers, ensure that the T-UNI LACP MLT on each peer is always associated with a VLAN, even if it is the default VLAN, and that it is added to a T-UNI I-SID. Otherwise, traffic is not forwarded on the T-UNI LACP MLT. 
About this task
You can configure Transparent Port UNI when either of the following apply:
- You want all tagged and untagged traffic on a port to be classified into the same broadcast domain. 
- You want to offer a transparent provider solution. 
Procedure
Example
Configure a Transparent Port UNI I-SID (elan-transparent based service).
Switch:1(config)#i-sid 3 elan-transparent Switch:1(elan-tp:3)#port 1/25 Adding Ports to Transparent UNI i-sid removes it from all VLANS. Do you wish to continue (y/n) ? y Switch:1(elan-tp:3)# Switch:1(elan-tp:3)#mlt 1 Adding MLTs to Transparent UNI i-sid removes it from all VLANS. Do you wish to continue (y/n) ? y Switch:1(elan-tp:3)#
Verify Transparent Port UNI or Elan-Transparent based service configuration.
Switch:1(config)#show i-sid 3
===============================================================================
                                      Isid Info
================================================================================
ISID        ISID               PORT            MLT            ORIGIN      ISID
ID          TYPE     VLANID    INTERFACES      INTERFACES                 NAME
--------------------------------------------------------------------------------
3           ELAN_TR    N/A      -               -             CONFIG      ISID-3
Variable definitions
The following table defines parameters for the i-sid command.

Note
When SPB is enabled, ISID IDs 16000000 (0xF42400) and greater, up to 16,777,215 (0xFFFFFF), are reserved for dynamic i-sid allocation and used to support IP Multicast traffic over SPB and other advanced Fabric services.
| Variable | Value | 
|---|---|
| i-sid <1–16777215> elan-transparent | Creates an Elan-Transparent based service. The service interface identifier (I-SID) range is 1 to 16777215. | 
| port {slot/port[/sub-port][-slot/port[/sub-port]][,...]} | Add ports to the Elan-Transparent based service. | 
| mlt<1–512> | Add MLTs to the Elan-Transparent based service. The MLT range is 1 to 512. | 