View the VLACP Port Configuration
View the VLACP port configuration to show the port VLACP configuration.
Procedure
Example
Switch:1>show vlacp interface gigabitethernet
============================================================================================
VLACP Information
============================================================================================
INDEX ADMIN OPER PORT FAST SLOW TIMEOUT TIMEOUT ETHER MAC
ENABLED ENABLED STATE TIME TIME TIME SCALE TYPE ADDR
--------------------------------------------------------------------------------------------
1/1 false false DOWN 200 30000 long 3 0x8103 01:80:c2:00:11:00
1/2 false false DOWN 200 30000 long 3 0x8103 01:80:c2:00:11:00
1/3 false false DOWN 200 30000 long 3 0x8103 01:80:c2:00:11:00
1/4 false false DOWN 200 30000 long 3 0x8103 01:80:c2:00:11:00
1/5 false false DOWN 200 30000 long 3 0x8103 01:80:c2:00:11:00
--More-- (q = quit)
============================================================================================
VLACP Flap Detect Information
============================================================================================
INDEX FLAP FLAP FLAP TOTAL FIRST-FLAP LAST-FLAP
DETECT FREQ INTERVAL FLAP TIME TIME
--------------------------------------------------------------------------------------------
1/1 false 3 60 0 -- -- -- --
1/2 false 3 60 0 -- -- -- --
1/3 false 3 60 0 -- -- -- --
1/4 false 3 60 0 -- -- -- --
1/5 false 3 60 0 -- -- -- --
--More-- (q = quit)
Switch:1>show vlacp interface gigabitethernet 2/11 vid 2
=========================================================================================================
VLACP Information
=========================================================================================================
INDEX ADMIN OPER PORT FAST SLOW TIMEOUT TIMEOUT ETHER MAC
ENABLED ENABLED STATE TIME TIME TIME SCALE TYPE ADDR
---------------------------------------------------------------------------------------------------------
2/11 true true up 500 30000 short 3 0x8103 01:80:c2:00:00:0f
=========================================================================================================
VLACP Flap Detect Information
=========================================================================================================
INDEX FLAP FLAP FLAP TOTAL FIRST-FLAP LAST-FLAP
DETECT FREQ INTERVAL FLAP TIME TIME
---------------------------------------------------------------------------------------------------------
2/11 true 10 10 4 09/20/11 08:24:10 09/20/11 08:26:10
Switch:1>show vlacp interface gigabitethernet 1/7
====================================================================================================
VLACP Information
====================================================================================================
INDEX ADMIN OPER PORT FAST SLOW TIMEOUT TIMEOUT ETHER MAC
ENABLED ENABLED STATE TIME TIME TIME SCALE TYPE ADDR
----------------------------------------------------------------------------------------------------
1/7 false false DOWN 200 30000 long 3 0x8103 01:80:c2:00:11:00
====================================================================================================
VLACP Flap Detect Information
====================================================================================================
INDEX FLAP FLAP FLAP TOTAL FIRST-FLAP LAST-FLAP
DETECT FREQ INTERVAL FLAP TIME TIME
----------------------------------------------------------------------------------------------------
1/7 false 3 60 0 -- -- -- --
Variable definitions
Use the data in the following table to use the show vlacp interface gigabitethernet command.
|
Variable |
Value |
|---|---|
|
vid <1-4059> |
Specifies the VLAN ID in the range of 1 to 4059. By default, VLAN IDs 1 to 4059 are configurable and the system reserves VLAN IDs 4060 to 4094 for internal use. On switches that support the vrf-scaling and spbm-config-mode boot configuration flags, if you enable these flags, the system also reserves VLAN IDs 3500 to 3998. VLAN ID 1 is the default VLAN and you cannot create or delete VLAN ID 1. The VLAN ID is in one of the following formats: A single VLAN ID (vlan-id), a range of VLAN IDs [(vlan-id)-(vlan-id)] or a series of VLAN IDs (vlan-id, vlan-id, vlan-id). |
|
{slot/port[/sub-port] [-slot/port[/sub-port]] [,...]} |
Specifies a port or list of ports to show only the VLACP information for those ports. Identifies the slot and port in one of the following formats: a single slot and port (slot/port), a range of slots and ports (slot/port-slot/port), or a series of slots and ports (slot/port,slot/port,slot/port). If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port. |