Edit Chassis Information
About this task
Edit the chassis information to make changes to chassis-wide settings.
Procedure
- In the Device Physical View tab, select the device.
- In the navigation pane, expand .
- Select Chassis.
- Select the Chassis tab.
- Edit the necessary options.
- Select Apply.
Chassis Field Descriptions
Use the data in the following table to use the Chassis tab.
Name |
Description |
---|---|
Type |
Specifies the chassis type. |
ModelName This parameter does not appear on all platforms. |
Specifies the chassis model name. |
BrandName This parameter does not appear on all platforms. |
Specifies the chassis brand name. |
PartNumber |
Specifies the device part number. |
SerialNumber |
Specifies a unique chassis serial number. |
HardwareRevision |
Specifies the current hardware revision of the device chassis. |
NumSlots |
Specifies the number of slots available in the chassis. |
NumPorts |
Specifies the number of ports currently installed in the chassis. |
BaseMacAddr |
Specifies the starting point of the block of MAC addresses used by the switch for logical and physical interfaces. |
MacAddrCapacity |
Specifies the number of routable MAC addresses based on the BaseMacAddr. |
Temperature This parameter does not appear for all platforms. |
Specifies the temperature of the device. |
MacFlapLimitTime This parameter does not appear for all platforms. |
Configures the time limit for the loop-detect feature, in milliseconds, for MAC flapping. The value ranges from 10–5000. The default value is 500. |
AutoRecoverDelay |
Specifies the time interval, in seconds, after which auto-recovery runs on ports to clear actions taken by CP Limit or link flap. The default is 30. |
MTUSize |
Configures the maximum transmission unit size. The default is 1950. |
MgidUsageVlanCurrent |
Number of MGIDs for VLANs currently in use. |
MgidUsageVlanRemaining |
Number of remaining MGIDs for VLANs. |
MgidUsageMulticastCurrent |
Number of MGIDs for multicast currently in use. |
MgidUsageMulticastRemaining |
Number of remaining MGIDs for multicast. |
DdmMonitor |
Enables or disables the monitoring of the DDM. When enabled, the user gets the internal performance condition (temperature, voltage, bias, Tx power and Rx power) of the SFP/XFP. The default is disable. |
DdmMonitorInterval |
Configures the DDM monitor interval in the range of 5 to 60 in seconds. If any alarm occurs, the user gets the log message before the specific interval configured by the user. The default value is 5 seconds. |
DdmTrapSend |
Enables or disables the sending of trap messages. When enabled, the trap message is sent to the Device manager, any time the alarm occurs. The default is enable. |
DdmAlarmPortdown |
Sets the port down when an alarm occurs. When enabled, the port goes down when any alarm occurs. The default is disable. |
PowerUsage This parameter does not appear on all platforms. |
Specifies the amount of power the CPU uses. |
PowerAvailable This parameter does not appear on all platforms. |
Specifies the amount of power available to the CPU. |