View DDI Temperature Information
About this task
This command displays information for DDI transceivers.
![Note](images/note.png)
Note
Transceiver support differs across hardware platforms. For information about supported parts, see Extreme Optics website.
Procedure
Example
Switch:1#show pluggable-optical-modules temperature ================================================================================ Pluggable Optical Module Temperature(C) ================================================================================ PORT LOW_ALARM LOW_WARN ACTUAL HIGH_WARN HIGH_ALARM THRESHOLD NUM THRESHOLD THRESHOLD VALUE THRESHOLD THRESHOLD STATUS -------------------------------------------------------------------------------- 1/2 7.0 1.1250 65.2539 0.0 3.0156 Low Alarm 1/3 7.0 1.1250 65.2539 0.0 3.0156 Low Alarm 1/9 7.0625 0.0 65.2539 0.0 3.0156 Low Alarm 1/15 7.0625 0.0 65.2539 0.0 3.0156 Low Alarm 2/1 7.0625 0.0 65.2539 0.0 3.0156 Low Alarm 2/17 7.0625 0.0 65.2539 0.0 3.0156 Low Alarm 2/40 7.0625 0.0 65.2539 0.0 3.0156 Low Alarm
Variable Definitions
Use the data in the following table to use the show pluggable-optical-modules temperature command.
Variable |
Value |
---|---|
{slot/port[/sub-port][-slot/port[/sub-port]][,...]} |
Identifies the slot and port in one of the following formats: a single slot and port (slot/port), a range of slots and ports (slot/port-slot/port), or a series of slots and ports (slot/port,slot/port,slot/port). If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port. |