Sets a device‘s system clock. By default all WiNG devices are shipped with the time zone and time format set to UTC and 24-hour clock respectively. If a device‘s clock is set without resetting the time zone, the time is displayed relative to the Universal Time Coordinated (UTC) – Greenwich Time. To display time in the local time zone format, in the device‘s configuration mode, use the timezone command. You can also reset the time zone at the RF Domain level. When configured as RF Domain setting, it applies to all devices within the domain. We recommend that you reset the local time zone on the device prior to setting the clock.
Note
This command and its syntax is common to both the User Executable and Privilege Executable configuration modes.
clock set <HH:MM:SS> <1-31> <MONTH> <1993-2035> {on <DEVICE-NAME>}
clock set <HH:MM:SS> <1-31> <MONTH> <1993-2035> {on <DEVICE-NAME>}
clock set |
Sets a device's software system clock |
<HH:MM:SS> |
Sets the current time (in military format hours, minutes, and seconds) Note:
By default, the WiNG software displays time in the 24-hour clock format. This setting cannot be changed. |
<1-31> |
Sets the numerical day of the month |
<MONTH> |
Sets the month of the year (Jan to Dec) |
<1993-2035> |
Sets a valid four digit year from 1993 - 2035 |
on <DEVICE-NAME> |
Optional. Sets the clock on a specified device
|
ap510-133B3B(config-device-94-9B-2C-13-3B-3B)#America/Los_Angeles
ap510-133B3B>clock set 00:46:06 8 Jan 2019
ap510-133B3B>show clock 2019-01-08 00:51:34 PST ap510-133B3B>