username
Configures a vEX3500 switch user settingsThe EX3500 switch user details
are stored in a local database on the NX 95XX, NX 96XX, NX 7510, or WiNG VM. You
can configure multiple users, each having a unique name, access level, and
password.
Supported in the following platforms:
- Service Platforms — NX 95XX, NX 96XX, NX 7510
Syntax
username <USER-NAME> [access-level <0-15>|nopassword|password [0|7] <PASSWORD>]
Parameters
username <USER-NAME> [access-level <0-15>|nopassword|password [0|7] <PASSWORD>]
username <USER-NAME> |
Configures the TACACS server port username
- <USER-NAME> – Specify the user name (should not exceed 32 characters)
|
access-level <0-15> |
Configures the access level for this user. This value determines the access
priority of each user requesting access and interoperability with EX3500 switch.
- <0-15> – Specify the
access level from 0 - 15. The default is 0.
|
nopassword |
Allows user to login without a password |
password [0|7] <PASSWORD> |
Configures the password for this user
- 0 – Configures a plain text password
- 7 – Configures an encrypted password (should be 32 characters in length)
- <PASSWORD> – Specify the password.
|
Examples
nx9500-6C8809(config-ex3500-management-policy-test)#username user1 access-level 5
nx9500-6C8809(config-ex3500-management-policy-test)#username user1 password 0 user1@1234
nx9500-6C8809(config-ex3500-management-policy-test)#show context
ex3500-management-policy test
ssh server
ssh authentication-retries 4
ssh timeout 90
ssh server-key size 600
http secure-server
enable password level 3 7 12345678901020304050607080929291
username user1 access-level 5
username user1 password 7 5c4786c1e52f913d38168ce89154a079
snmp-server enable traps authentication
snmp-server notify-filter 3 remote 1.2.3.4
snmp-server notify-filter 1 remote 127.0.0.1
--More--
nx9500-6C8809(config-ex3500-management-policy-test)#