output-power
(iot-device-type-imagotag-policy)
Configures the maximum output power for
the ESL communicator.
Supported in the following platforms:
- Access Points — AP-8432
- Wireless Controllers — RFS 4000
- Service Platforms — NX 5500, NX 75XX, NX 95XX, NX 96XX, VX 9000
Syntax
output-power [Level-A|Level-B|Level-C|Level-D|Level-E|Level-F|Level-G|Level-H]
Parameters
output-power [Level-A|Level-B|Level-C|Level-D|Level-E|Level-F|Level-G|Level-H]
output-power
[Level-A|Level-B|Level-C|Level-D|Level-E|Level-F|Level-G|Level-H] |
Configure the ESL communicator‘s output power in dBm.
The options are:
- Level-A – 1 dBm. This is the default setting.
- Level-B - -4 dBm
- Level-C - -6 dBm
- Level-D - -12 dBm
- Level-E - 0 dBm
- Level-F - -2 dBm
- Level-G - -8 dBm
- Level-H - -10 dBm
Note: SES-Imagotags recommends NOT to change the default
setting, which is in conformance to various country/region specific RF
regulations.
|
Examples
nx9500-6C8809(config-iot-device-type-imagotag-policy-ImagoTagPolicy)#output-power Level-B
nx9500-6C8809(config-iot-device-type-imagotag-policy-ImagoTagPolicy)#show context
iot-device-type-imagotag-policy ImagoTagPolicy
enable
output-power Level-B
fcc-enable
channel 9
nx9500-6C8809(config-iot-device-type-imagotag-policy-ImagoTagPolicy)#