Use this command to enable a remote MEP in the database for the current MEP.
remote-mep-id | Specifies the remote MEP to enable in the database for the current MEP. Valid values are 1 - 8191. |
End-points in the remote MEP database default to disabled.
Maintenance End-Point Configuration mode.
The local MEP exchanges continuity check messages with the remote MEP if the remote MEP is set to active. You must enable a remote MEP within the local MEP configuration context for the remote MEP to exchange PDUs with the local MEP and to be considered for defect generation.
Use mep-list to enter remote MEPs into the remote MEP database.
The “no” form of this command disables the specified remote MEP in the database of the current MEP.
This example shows how to enable remote MEP 2000 in the myMA1 MEP 1000 database:
System(rw-config)->cfm md string-name myMD1 System(su-config-cfm-md.1)->ma string-name myMA1 System(su-config-cfm-ma.1)->mep 1000 System(su-config-cfm-mep.1000)->remote-mep 2000 active System(su-config-cfm-mep.1000)->