show inlinepower

Use this command to display device PoE properties.

Syntax

show inlinepower

Parameters

None.

Defaults

None.

Mode

All command modes.

Usage

The show inlinepower output will display eight powersupply status lines regardless of the number of bays in the PoE power shelf. It a power supply bay does not exist or there is no power supply installed, the status will read “not installed.”

Example

This example shows how to display PoE properties for this chassis.

System(rw)->show inlinepower
Total Power Detected    : 2400 Watts
Total Power Available   : 2400 Watts (100% of Total Power Detected)
Total Power Assigned    : 0 Watts
Power Allocation Mode   : auto
Power Trap Status       : disabled
Power Redundancy Status : not supported
Power Supply 1 Status   : installed and operating
Power Supply 2 Status   : not installed
Power Supply 3 Status   : not installed
Power Supply 4 Status   : installed and operating
Power Supply 5 Status   : not installed
Power Supply 6 Status   : not installed
Power Supply 7 Status   : not installed
Power Supply 8 Status   : not installed
Slot Oper   Power Power    Power     Class  Power Usage Usage PSE      Mgmt
     Status Limit Assigned Available Budget Usage       Trhld Trap     Mode
            (W)   (W)      (W)       (W)    (W)   (%)   (%)   Status
---- ------ ----- -------- --------- ------ ----- ----- ----- -------- ---------
1    on     1632  0        563              2     0     75    disabled real-time
2                 0
3                 0
4                 0
5                 0
6    on     2040  0        704              3     0     75    disabled real-time
7    on     1632  0        563              2     0     75    disabled real-time
8    off    1632  0        564              0     0     75    disabled real-time