Use this command to set the frequency of LLDP PDU transmissions while in fast transmission state.
frequency | Specifies the number of seconds between LLDP PDU transmissions when in fast transmission state. Value can range from 1 to 3600 seconds. The default is 1 second. |
None.
All command modes.
LLDP PDU packets are sent once every 30 seconds by default. When a new neighbor is discovered, it is desirable for packets to be sent more frequently. LLDP enters fast transmission state. This command specifies the length of the fast transmission state interval. In fast transmission state, an LLDP PDU packet will be sent each fast transmission state interval for the number of intervals specified by the fast transmission state count. The fast transmission state count is set using the command.
This example sets the number of seconds between LLDP PDU packets when in fast transmission state to 4.
System(rw)->set lldp tx-fast-interval 4