Use this command to display port transceiver information.
| port-string | (Optional) Displays transceiver information for the specific port(s). |
| basic-only | (Optional) Displays basic transceiver information only for the port context. |
| sensor-only | (Optional) Displays sensor transceiver information only for the port context. |
| all | (Optional) Displays all transceiver information for the port context. |
If no options are specified, all transceiver information is displayed for all transceiver ports.
All command modes.
This example shows how to display all transceiver information, including basic data and sensor data, for tg.1.5:
System(rw)->show port transceiver tg.1.5
Port Vendor Vendor
Name Serial Number
----------- ---------------- ----------------
tg.1.5 AVAGO AD1230LE0GX
Port Sensor Data Value Alarm High High Low Low
(Units) State Alarm Warning Warning Alarm
Threshold Threshold Threshold Threshold
----------- -------------------- ---------- ----------- ---------- ---------- ---------- ---------
tg.1.5 Temp (C) 36 NORMAL 75 70 0 -5
tg.1.5 Voltage (V) 3.251 NORMAL 3.630 3.465 3.134 2.970
tg.1.5 TX Current (mA) 35.658 NORMAL 80.000 74.000 12.000 10.000
tg.1.5 TX Power (mW) 0.643 NORMAL 2.238 1.122 0.151 0.060
tg.1.5 TX Power (dBm) -1.918 NORMAL 3.499 0.500 -8.210 -12.218
tg.1.5 RX Power (mW) 0.013 LOW ALARM 2.238 1.122 0.036 0.014
tg.1.5 RX Power (dBm) -18.861 LOW ALARM 3.499 0.500 -14.437 -18.539
This example shows how to display basic information only for all ports with transceivers present:
System(rw)->show port transceiver basic-only
Transceiver Data (operational transceivers only)
--------------------------------------------------
Port Vendor Vendor
Name Serial Number
----------- ---------------- ----------------
ge.1.23 FINISAR CORP. PKS2XDD
ge.1.47 AGILENT AC0548SJ102
tg.1.3 AVAGO AD1230LE0GX
tg.1.4 AVAGO AD1230LE0GX
tg.1.5 AVAGO AD1230LE0GX
tg.1.6 AVAGO AD1230LE0GX
tg.1.7 TE Connectivity2 12090001
tg.1.8 TE Connectivity2 12090001
tg.1.9 TE Connectivity2 12090001
tg.1.10 TE Connectivity2 12090001
This example shows how to display sensor information only for tg.1.3 and tg.1.4
System(rw)->show port transceiver tg.1.3-4 sensor-only
Transceiver Sensor Data (operational sensors only)
--------------------------------------------------
Port Sensor Data Value Alarm High High Low Low
(Units) State Alarm Warning Warning Alarm
Threshold Threshold Threshold Threshold
----------- -------------------- ---------- ----------- ---------- ---------- ---------- ---------
tg.1.3 Temp (C) 36 NORMAL 75 70 0 -5
tg.1.3 Voltage (V) 3.251 NORMAL 3.630 3.465 3.134 2.970
tg.1.3 TX Current (mA) 36.126 NORMAL 80.000 74.000 12.000 10.000
tg.1.3 TX Power (mW) 0.644 NORMAL 2.238 1.122 0.151 0.060
tg.1.3 TX Power (dBm) -1.911 NORMAL 3.499 0.500 -8.210 -12.218
tg.1.3 RX Power (mW) 0.013 LOW ALARM 2.238 1.122 0.036 0.014
tg.1.3 RX Power (dBm) -18.861 LOW ALARM 3.499 0.500 -14.437 -18.539
tg.1.4 Temp (C) 36 NORMAL 75