set inlinepower psetrap

Use this command to enable or disable the sending of an SNMP trap message for a module whenever the status of its ports changes, or whenever the module‘s PoE usage threshold is crossed.

Syntax

set inlinepower psetrap {disable | enable} module-number

Parameters

disable | enable Disables or enables PoE trap messaging.
module-number Specifies the module on which to disable or enable trap messaging. If you are configuring this value on an S-Series, use 1 as the module number.

Defaults

Disabled.

Mode

All command modes.

Usage

The module‘s PoE usage threshold must be set using the set inlinepower threshold command as described in set inlinepower threshold.

Example

This example shows how to enable PoE trap messaging on module 1:

System(rw)->set inlinepower psetrap enable 1