show system hardware

Use this command to display the system‘s hardware configuration.

Syntax

show system hardware

Parameters

None.

Defaults

None.

Mode

All command modes.

Example

The following S-Series SSA example shows a portion of the information displayed with the show system hardware command.

Note

Note

Depending on the hardware configuration of your S- K- and 7100-Series system, your output will vary from the example shown.
System(su)->show system hardware
CHASSIS HARDWARE INFORMATION
----------------------------
   Chassis Type:               S-Series Standalone (SSA)
   Chassis Serial Number:      094454536352
   Chassis Power Supply 1:     Installed & Operating, AC High Power, Not Redundant
   Chassis Power Supply 2:     Not Installed
   Chassis Fan 1:              Installed & Operating
   Chassis Fan 2:              Installed & Operating
   Chassis Fan 3:              Installed & Operating
   Chassis Fan 4:              Installed & Operating
   Chassis Fan 5:              Installed & Operating
   Chassis Fan 6:              Installed & Operating
   Chassis Fan 7:              Installed & Operating
   Chassis Fan 8:              Installed & Operating
   Chassis Fan 9:              Installed & Operating
   Chassis Fan 10:             Installed & Operating
   Chassis Fan 11:             Installed & Operating
   Chassis Fan 12:             Installed & Operating
   Chassis Fan 13:             Installed & Operating
   PoE Power Supply 1:         Installed & Operating
   PoE Power Supply 2:         Not Installed
SLOT HARDWARE INFORMATION
-------------------------
   SLOT 1
      Model:                   SSA-T4068-0252
      Part Number:             9404332
      Serial Number:           094454536352
      Vendor ID:               1
      Base MAC Address:        00-1F-45-5B-F5-CF
      MAC Address Count:       54
      Hardware Version:        1
      Firmware Version:        07.11.01.0011.daveh4BFD5B25
      BootCode Version:        01.00.21x
      BootPROM Version:        01.01.05
      CPU Version:             28674 (PPC 750GX)
      SDRAM:                   1024 MB
      NVRAM:                   32  KB
      Flash System:            1024 MB
         /flash0 free space:   37  MB
         /flash1 free space:   62  MB
         /flash2 free space:   803 MB
      Temperature:
         LM75:                 33.500  C
      Dip Switch Bank          1    2    3    4    5    6    7    8
         Position:             OFF  OFF  OFF  OFF  OFF  OFF  OFF  OFF
      HOST CHIP:
         Type:                 FPGA
         Revision:             839   (0x347)
      FABRIC ACCESS PROC CHIP:
         FAP CHIP [0]:         FAP21V Revision A
         FAP CHIP [2]:         FAP21V Revision A
      FABRIC ELEMENT CHIP:
         FEs:                  Not present
      PLD CHIP:
         Revision:             3     (0x3)
      NIM[0]:
         Location:             lower left
         Model:                48 Port 10/100/1000 RJ45, 4X, Quad-Wide Bottom, PoE+ Capable
         Board Revision:       5     (0x5)
         PLD Revision:         5     (0x5)
         FRU:                  no
         PoE[0]:
            Software Revision: 04.00.01.02
            Device Id:         0xe103
         SWITCH CHIP[0]:
            Type:              ASIC
            Revision:          0    (0x0)
            Id:                0
.
.
.
System(su)->