Use this command to set the OAM loopback mode for the specified port.
port-string | Specifies the port(s) to configure for OAM loopback mode. For a detailed description of possible port-string values, refer to Port String Syntax Used in the CLI in the S-, K-, and 7100 Series Configuration Guide. |
ignore | process | Set the OAM loopback mode for a port. The default value is ignore. |
None.
All command modes.
Determines the behavior of the OAM client when receiving a remote loopback request from a remote OAM client. Setting this value to process will allow the OAM client to receive and operate upon an OAM PDU request. Setting this value to ignore will force the OAM client to discard any received remote loopback OAM PDUs. The default value is ignore.
This example shows how to set the OAM client behavior on port ge.1.3 to receive and operate upon OAM PDU requests:
System(rw)->set port oam ge.1.3 loopback-rx process