Configure Interface SPBM Parameters
Use the following procedure to configure the SPBM interface parameters.
Procedure
- In the navigation pane, expand .
 - Select SPBM.
 - Select the Interfaces SPBM tab.
 - Configure the SPBM interface parameters.
 - Select Apply.
 
Interfaces SPBM Field Descriptions
Use the data in the following table to use the Interfaces SPBM tab.
| 
                         Name  | 
                    
                         Description  | 
                
|---|---|
| 
                         Index  | 
                    
                         Specifies an Index value for the SPBM interface.  | 
                
| 
                         SpbmId  | 
                    
                         Specifies the SPBM ID.  | 
                
| 
                         State  | 
                    
                         Specifies whether the SPBM interface is enabled or disabled.  | 
                
| 
                         Type  | 
                    
                         Configures the SPBM instance interface-type on the IS-IS interface located on the specified port or MLT: ptpt or bcast. Only the point-to-point (ptpt) interface type is supported.  | 
                
| 
                         L1Metric  | 
                    
                         Configures the IS-IS Interface level 1 metric on the specified port or MLT. The default value is 10.  | 
                
| Origin Note: 
                                     
Exception: not supported on VSP 8600 Series or XA1400 Series.  | 
                            
                                 Specifies the source of the SPBM instance configuration, either manually configured through CLI or EDM, or dynamically configured through Auto-sense.  |